Not quite. The answer is C: 5 by 10 one half in.
The table lists 5 by 10 one half in (net) for glulam beams and girders carrying floor loads. The 6 by 10 figure is the nominal sawn size for the same member; reading glulam as nominal sawn is a listed common error. The 5¼ by 9 one half in figure is the structural composite lumber (SCL) minimum for floor beams. The 6¾ by 8¼ in figure is the glulam minimum for columns carrying floor loads.

0 of 1 right so far.

Question 2 of 10.

Which lumber fireblock complies with IBC 718.2.1?

A: Two thicknesses of 1 in nominal lumber with aligned joints
B: One layer of 1 in nominal lumber
C: Two thicknesses of 1 in nominal lumber with broken lap joints
D: One layer of 1 one half in nominal lumber

NEXT: A · B · C · D